Screw type flow meters SVC
HIGHLY PRECISE AND ROBUST
Our screw type flow meters incorporate the product characteristics robustness, high-precision measuring accuracy, good handling as well as durability and economy. Further advantages are resistance and insensitivity to contamination, pulsation free and low pressure drop.
SCREW TYPE FLOW METERS SVC
Particularly suitable for highly viscous media with abrasive fillers.

CHARACTERISTICS
Measuring range: 0.4 … 3 750 l/min
Media temperature: -40 … 210 °C
Maximum pressure: … 480 bar
APPLICATIONS
> Fuel consumption measurement
> Dosing systems
> Process technology
> Test bench construction
> Dosing systems
> Process technology
> Test bench construction
PRODUCT CHARACTERISTICS
> High-precision measurement with outstanding reproducibility
> Pulsation-free measuring principle
> Very low pressure drop
> Any flow direction
> Wide temperature range
> High working pressure
> High-response measurement
> Very low noise emission
> Electronics in EMC compliant design
> RoHS compliant
> Pulsation-free measuring principle
> Very low pressure drop
> Any flow direction
> Wide temperature range
> High working pressure
> High-response measurement
> Very low noise emission
> Electronics in EMC compliant design
> RoHS compliant
Options
> ATEX version
Data sheets
contact
SCREW TYPE FLOW METERS SVC WITH ENCODER
With maximized measured value resolution for high-precision measurements in process and test bench technology.

CHARACTERISTICS
Measuring range: 1.0 … 150 l/min
Media temperature: -20 … 80 °C
Maximum pressure: … 250 bar
Media temperature: -20 … 80 °C
Maximum pressure: … 250 bar
APPLICATIONS
> Process technology
> Test bench construction
> Test bench construction
PRODUCT CHARACTERISTICS
> Basic device identical to standard SVC
> Maximized measurement resolution up to 247 463 Imp/l
> Maximized measurement resolution up to 247 463 Imp/l
Data sheets
contact
SCREW TYPE FLOW METERS SVC WITH IO-LINK TECHNOLOGY
Signal conversion with internal calculation of measured values.

CHARACTERISTICS
Measuring range: 0.4 … 3 750 l/min
Media temperature: -30 … 80 °C
Maximum pressure: … 480 bar
APPLICATIONS
> Process technology
> Test bench construction
> Test bench construction
PRODUCT CHARACTERISTICS
> Basic device identical to standard VC
> Output of square-wave signals in SIO mode
> Output of specific measured values in IO-Link mode
> Simplified commissioning through IODD file (IO Device Description)
> Output of square-wave signals in SIO mode
> Output of specific measured values in IO-Link mode
> Simplified commissioning through IODD file (IO Device Description)
IODD Download
On request
Data sheets
contact
SCREW TYPE FLOW METERS SVC WITH analogue TECHNOLOGY
For control units or measuring devices with standard analogue current inputs.

CHARACTERISTICS
Measuring range: 0.4 … 3 750 l/min
Media temperature: -30 … 80 °C
Maximum pressure: … 480 bar
APPLICATIONS
> Process technology
> Test bench construction
> Test bench construction
PRODUCT CHARACTERISTICS
> Basic device identical to standard SVC
> Analogue output signal for flow rate determination
> Additional digital signal for flow direction determination
> Individualisation of the measuring range possible
> Universal application possibilities
> 16 bit resolution
> Cable break detection
> Display of flow rate and direction by proportional LED behaviour on the device
> Analogue output signal for flow rate determination
> Additional digital signal for flow direction determination
> Individualisation of the measuring range possible
> Universal application possibilities
> 16 bit resolution
> Cable break detection
> Display of flow rate and direction by proportional LED behaviour on the device